With the ability to support a wide range of communication protocols and applications, the D20 is interoperable with a broad range of intelligent electronic slave and master devices. It can execute simple to complex local logic, compile and process data, and report upstream to master stations. The D20's distributed, expandable I/O architecture and mission-critical automation control applications have made it the controller of choice in over 40,000 installations worldwide.
.png)
Substation client and server functionality: Maintains a distributed architecture for gathering and controlling data on substation equipment while sending data to master stations via serial RS-232, RS-485, fibre optic, or Ethernet interfaces for point-to-point, multi-drop, and remote connections.
Broad protocol support: Supports a wide range of SCADA host protocols, IED protocols, communication options, I/O peripheral modules, and operation and maintenance utilities.
Proven design: The D20's design and processing capabilities make it a flexible and reliable RTU or Gateway.
Extensive protocol library: More than 100 communication protocols and applications.
Scalable configurations: Simple to complex substation configurations with advanced automation applications.
Easy commissioning: User-friendly commissioning and maintenance facilities ensure accurate RTU settings prior to live installations.
Complete family of substation-hardened I/O modules provides scalability for large and small installations.
Distributed architecture allows redundancy of I/O modules to increase reliability.
Wide range of modules available with I/O ranges up to 300 VDC and support for DNP3 and GE Vernova's D.20 protocol.
D20S | 64-channel status input module |
D20A | 32-channel DC analog input module |
D20K | 32-channel control output module |
D20K1 | 8 external interposer relay pairs module |
D20C | 16 status inputs, 8 control outputs, optional 16 DC analog inputs or 8 analog inputs and 8 analog outputs |
D20AC | 15-channel direct AC input, 1 DC analog input module |
LogiLinx™ module: IEC 61131-3 compliant PLC-type logic with full support for 5 programming languages
Calculator module: Soft logic utility to perform mathematical and logical operations
Automatic Voltage Control: Maintains steady voltage based on user-defined targets and settings
Local/Remote Data Translation: Master local/remote switch to control the local/remote state of distributed devices
Secondary Master Trip/Close: Enables the use of individual relays as master trip/close relays
Set-point Adjustment: Adjusts set points based on control request durations or analog input values
Tap Position Indication: Translates status points into scaled analog input values to reflect transformer tap positions.
Auto Reclose: Automatically recloses tripped circuit breakers following momentary faults
Automatic Restoration: Patented load transfer scheme isolates faults and restores power to non-faulted sections
Distribution Capacitor Control Algorithm: Improves reactive support during peak periods
Fault Localization: Locates and isolates faults to reduce customer outage times
Load and Dead Bus Transfer: Monitors a network of substations and moves load off overloaded transformers
Load Shedding/Curtailment: Sheds load intelligently during overload conditions
SOE Local Logger: Logs digital and analog SOEs to an external printer, PC, or CSV file
Accumulator Freeze: Coordinates freezing of accumulator groups
Event Storage: Stores history of current values, status, and time-tags for up to 7 days
Historical Analog: Stores averaged historical values for up to 8 analog inputs
Communication Watchdog: Monitors and reports the health of communications
Substation Maintenance: Suppresses SCADA point reporting during substation maintenance
Virtual Terminal: Directs remote access to connected devices
Line Switch: Monitors main and secondary communication channels
LAN Services: TFTP, SPT Server/Client, Time Server/Client
COM Statistics: Records detailed communication pass/fail statistics
IRIG-B Source: Time sync connected devices using IRIG-B
SNTP Client: Time sync over an Ethernet LAN
Analog Reference: Monitors analog input hardware for good or bad reference values
Data Change Detect: Toggles a status point when any data in a configured group changes.
Alarm Prioritization: Manages 3-level alarms reported by GE Vernova's DART pole-top/pad-mount distribution RTU
Analog Averaging: Averages analog values at regular intervals
General Alarm: Groups alarms together to create summary alarms
Top of Hour Analog Averaging: Averages analogs relative to the top of the hour
Redundant I/O: Provides data from a backup source if the primary source is offline
Digital-Analog Value Conversion: Converts digital input groups to analog data using binary, BCD, or gray code encoding
Digital Input to Counter: Counts the number of SOE or COS transitions on status points
BCD Setpoint: Translates analog output requests into a group of BCD-encoded control points
Accumulator Delta to Analog: Converts accumulators to analog values for protocols that do not support counters
Time Stamp: Interprets each bit in an analog input as a status point
Analog to Digital Conversion: Converts analog inputs into groups of binary coded control outputs
Mailbox: Converts analog outputs into analog inputs so they can be read by all masters
AGA Gas Flow: Computes gas flow rate and energy flow rate calculations
Up to 2 D.20 ports, each supporting up to 31 I/O peripherals without repeaters, and 120 I/O peripherals with repeaters.
Up to 21 RS-232 or RS-485 ports (7 per processor board)
2 Ethernet channels
4 D.20 ports, each supporting up to 31 I/O peripherals without repeaters, and 120 I/O peripherals with repeaters
Up to 49 RS-232 or RS-485 ports (7 per D20ME or D20ME II Main Processor)
2 Ethernet channels
Optional redundant configuration for high reliability at critical sites
Importing and exporting XML representation of D2x devices
D25 KT control card support
D25 Ethernet 100/10 MB card support
Secure configuration transfer to/from D20 devices with D20MX processors over Ethernet connections
| IEC 60068-2-6 | Sinusoidal Vibration | 10 Hz to 150 Hz at 1 octave/min, 1g acceleration |
| IEC 60068-2-1 | Cold Test | -10°C for 16 hours |
| IEC 60068-2-2 | Dry Heat | 55°C to 70°C for 16 hours |
| IEC 60068-2-30 | Damp Heat Humidity | 25°C to 55°C, up to 95% RH, 6 cycles |
| IEC 60255-5:2001 | Impulse Voltage Withstand | 500 to 2000 V |
| IEC 60255-5:2001 | Dielectric Test | 710 to 1500 VDC |
| IEC 60255-5:2001 | Insulation Resistance | 1.5 GOhm min |
| CISPR 11:2006 | Conducted Emissions | 150 kHz – 30 MHz |
| CISPR 22:2008-09 | Radiated Disturbance | Class A |
| IEC 61000-4-2 | Electrostatic Discharge | Criteria/Class B |
| IEC 61000-4-3 | Radiated Immunity | 80 MHz – 1 GHz, Class A |
| IEC 61000-4-4 | Electrical Fast Transients | Criteria/Class B |
| IEC 61000-4-5 | Surge Immunity | Criteria/Class B |
| IEC 61000-4-6 | Conducted Immunity | 150 kHz – 80 MHz, Class A |
| IEC 61000-4-8 | Power Frequency Magnetic Field | Criteria/Class A |
| IEC 61000-4-11 | Voltage Dips and Interruptions | Criteria/Class B/C |
CPU/Memory | 32-bit Freescale 68030 microprocessor, 40 MHz MPU clock |
Real-time Clock | 1.0 ms resolution, accurate to ±2.0 ppm |
On-board Memory | 2 MB Flash, 2 MB SRAM (incl. 512 K battery backup), 512 KB BootROM |
Self Diagnostics | Program memory checksums, RAM test, configuration verification, interrupt controller verification, serial port test, watchdog and power monitor, peripheral communication checks, error logger |
Communications | Two HDLC ports for peripheral modules; 7 programmable RS-232/RS-485 ports; 38,400 kbps on all 7 ports; 9600 baud maintenance port |
Power Requirements | 3.5 W typical, 5 W maximum |
Physical | LED indications: Run/Halt and System Fail |
ABB® Inductive 33/41, 35
Conitel C3000, C0200, C2020, C2025, C2100, C2100M
DNP 3 (Serial, TCP/IP, UDP/IP)
IEC® 60870-5-101, IEC® 60870-5-104
Modbus® (Serial)
PG&E® (Rev. 11)
Siemens® Sinaut® 8FW-1024, 8FW-512
Telegyr® TG809
UCA™ 2.0
Westinghouse® REDAC 70H, WESDAC 4F, WISP+
Protection Relays
Power Meters
Digital Fault Recorders
Power Quality Monitors
Capacitor Bank Controllers
Load Tap Changer (LTC) Controllers
PLCs
D20 Single CPU (Non-VME): Single-slot chassis with one processor
D20 VME Multi-Node Gateway: Multiple-slot VME chassis with up to 2 processors
D200 Multi-Processor Gateway: 9-slot VME chassis with up to 4 processors
Proven Reliability | Over 40,000 installations worldwide |
Scalable Architecture | From single-slot D20 to multi-processor D200 |
Extensive Protocol Support | More than 100 communication protocols |
Distributed I/O | Substation-hardened modules with redundancy options |
Advanced Automation | Patented restoration, load transfer, and capacitor control algorithms |
Easy Configuration | ConfigPro and SGConfig software tools |
Rugged Design | Compliant with IEEE and IEC standards for harsh environments |