English
News
Get to know our latest news
GE IS200ADIIH: IS200 ADII Auxiliary ISBus Interface Board
Source: | Author:kongjiang | Published time: 2026-09-17 | 31 Views | 🔊 Click to read aloud ❚❚ ▶ | Share:
GE IS200ADIIH: IS200 ADII Auxiliary ISBus Interface Board

GE IS200ADIIH: IS200 ADII Auxiliary ISBus Interface Board

Overview

The IS200ADIIH is an Auxiliary ISBus (Innovation Series™ Bus) Interface Board (ADII) designed to interface an AcDc2000 drive to an ISBus Local Area Network (LAN). The board resides on the backside of the first board carrier of the AcDc2000 drive, providing a critical communication link between the drive and its control system.
This interface board is an essential component for integrating AcDc2000 drives into Innovation Series drive systems, enabling seamless data exchange and control functionality.

Functional Description

Communication Architecture

The ADII board connects to the DS200LDCC Drive Control/LAN Communications board (LDCC) through:
  • LNPL ribbon cable

  • COM1 wire

Power is supplied to the ADII board through the 2PL power cable from the AcDc2000 drive's power supply board.

Key Functional Features

  • Bypass Relay: The ADII board includes a bypass relay to maintain ISBus electrical continuity if the drive is powered down — no external bypass module is required.

  • Signal Mapping: The interface signal map is derived from the Innovation Series drive system applications signal map. Many references and feedbacks are generic, and AcDc2000 drive blockware must be created to imitate the Innovation Series drive functionality.

  • Integer Variable Mapping: The ADII board provides an integer variable map between the drive and controller. The integers must be scaled to the AcDc2000 units (given in the signal map definition).

Configuration

Configuration of the interface is done with either:
  • The local keypad on the LDCC board

  • The GE Control System Toolbox (toolbox)

Refer to the Data Mapping section for detailed configuration information.

Hardware Design

The ADII board has no fuses or hardware jumpers. For information on LED indicators, test points, and connectors, refer to the Application Data section.
Note: The ADII board can only be used in AcDc2000 drives that have the LDCC board. It cannot be used with previous design drive control and LAN communication boards.

Installation Procedures

⚠️ Safety Warnings

Warning: To prevent electric shock, turn off power to the drive, then test to verify that no power exists in the drive before touching it or any connected circuits.
Caution: To prevent equipment damage, do not remove, insert, or adjust board connections while power is applied to the equipment.

Step-by-Step Installation

  1. De-energize the drive: Make sure that the drive in which the board is to be installed has been de-energized. (Refer to the appropriate User's Guide for complete de-energizing procedures and follow all local practices of lock-out/tag-out.)

  2. Open the drive's cabinet door. Using equipment designed for high voltages, test any electrical circuits before touching them to ensure that power is off.

  3. Install the ADII board in the drive as follows:


    • a. Release the two board carrier retainers by pulling them forward.

    • b. Lift up and rotate the front board carrier out and down until it is resting on its stops.

    • c. Place the board in position on the four tabs (on the left side) of the back of this board carrier and press it firmly into position on these tabs.

  4. Connect the LNPL ribbon cable into the LNPL connector on the ADII board and the LNPL connector on the LDCC board.

  5. Connect the COM1 wire onto the E1 (COM1) stab-on terminal on the ADII board and the E1 (COM1) terminal on the LDCC board.

  6. Install the CHASSIS wire onto the E2 stab-on terminal on the ADII board and secure the other end to an accessible screw on the drive chassis.

  7. Caution: The chassis wire must be securely mounted to the drive's chassis to shunt the ISBus shield to ground. Care must be taken to keep the chassis wire tight to the ADII board and away from the power supply board at all times. Use a wire tie-down strap connected to the bottom of the board carrier to keep it away from the power supply board.

  8. Plug the 2PL cable connector into the 2PL receptacle on the ADII board.

  9. Install an ISBus cable into the RXIN RJ45 jack (P3) on the ADII board and the TXOUT jack (P2) of the previous device on the ISBus.

  10. Install an ISBus cable into the TXOUT RJ45 jack (P2) on the ADII board and the RXIN jack (P3) of the next device on the ISBus.


Compatibility & Requirements

Compatible Drive
AcDc2000 drive with LDCC board
Incompatible With
Previous design drive control and LAN communication boards
Configuration Tools
Local keypad on LDCC board or GE Control System Toolbox
Power Source
2PL power cable from AcDc2000 power supply board
Communication Interface
LNPL ribbon cable and COM1 wire to LDCC board

Why Choose the IS200ADIIH?

Seamless Integration
Directly interfaces AcDc2000 drives to ISBus LAN
No External Bypass Needed
Built-in bypass relay maintains ISBus continuity
Flexible Configuration
Configure via local keypad or GE Control System Toolbox
Robust Design
No fuses or hardware jumpers to fail
Clear Diagnostics
LED indicators, testpoints, and connectors for easy troubleshooting

IS200TSVCH1A

IS200TTURH1CFD

IS200TVBAH2ACC

IS200VCRCH1B

IS200VSVOH1B

IS200VSVOH1BDC

IS200VTURH2BAC

IS200VVIBH1CAC

IS200WNPSH1ABA

IS210AEBIH1BED

IS210AEDBH4AGD

IS210SAMBH2AA

IS210WSVOH1AE

IS215UCVEH2A

IS215UCVEM06A

IS215UCVEM09B

IS215VCMIH2C

IS215VPROH1BD

IS220PAICH2A

IS220PDIAH1B

IS220PDIOH1B

IS220PRTDH1A

IS220PRTDH1B

IS220PSVOH1A

IS220PSVOH1B

IS220PTURH1B

IS220UCSAH1A

IS220YDIAS1A

IS230SNCIH6A

IS230TCISH6C

IS230TNCIH4C

IS230TVBAH2A

IS420UCSBH1A