Introduction

The Emerson DeltaV KJ1501X1-BA2 System Power Supply is a vital component of the DeltaV M-series Traditional I/O subsystem, providing reliable AC-to-DC power conversion for field devices and I/O interfaces. As part of Emerson's field-proven DeltaV architecture, this power supply ensures stable, uninterrupted power distribution across your process control infrastructure.
Traditional I/O is a modular subsystem that offers flexibility during installation. It is designed to be installed in the field, near your devices. Traditional I/O is equipped with function and field wiring protection keys to ensure that the correct I/O card is always plugged into the corresponding terminal block. Modularity, protection keys, and plug-and-play capabilities make DeltaV Traditional I/O a smart choice for your process control system.
Whether you are maintaining an existing DeltaV installation, expanding your M-series I/O footprint, or sourcing hard-to-find spares, the KJ1501X1-BA2 remains a trusted choice for engineers and procurement teams worldwide.

Key Benefits

Decreases Capital Equipment Costs

Full System Modularity: The Traditional I/O subsystem was designed with your investment in mind. All components are fully modular and may be installable under power. You add I/O interface carriers and I/O interfaces in groups of 4, 8, 16, or 32 channels as you need them. The modular design enables you to purchase the exact amount of I/O cards, 8-wide or 4-wide carriers, power/controllers, and 2-wide carriers you need — and add more DeltaV I/O as your system grows.
Reduced System Footprint: The DeltaV system's state-of-the-art form factor design of the I/O components enables you to mount the I/O interface carrier in a junction box in the field, significantly reducing the footprint of your equipment and increasing valuable control room space for other uses.
Installation Savings: Save on wiring expenses by installing Classic Instrumentation in the field, near the actual field devices. Mounting the controller with the I/O further reduces your wiring expenditures by eliminating the need for long runs of multi-cores. The integrated design of the Traditional I/O subsystem can eliminate the need for marshalling panels — saving you even more in total capital costs. The provision of in-line fuses and bussed power saves on installation costs compared with external fuses and power distribution.

Decreases Installation Time and Expense

Plug-and-Play Installation Saves Money: All Traditional I/O components plug into the I/O interface carrier. You can install the I/O interface carriers to manage anticipated growth and postpone the I/O interfaces until you are ready to install your additional field devices.
Phased Installation Saves Time: As soon as you mount the I/O interface carrier, you are ready to begin installing the field devices. I/O terminal blocks plug directly onto the I/O interface carrier. There is no need to have the I/O cards installed.
Keys: Traditional I/O interfaces and terminal blocks have I/O function keys. These keys ensure that the correct I/O card is always plugged into the corresponding terminal block. It is incredibly easy to use and gives you time to do more. This design enables you to initially install Traditional I/O quickly and efficiently. When you need to replace an I/O card, the function key design ensures that you will always install it correctly. This keying system provides a safety measure by preventing the wrong I/O interface from being installed.

Increases Productivity

Real-Time, Online Equipment Additions: Online addition of new I/O interfaces means your process does not get interrupted. As new equipment is added, the DeltaV Explorer acknowledges it and assigns it basic configuration.

Increases Process Availability

1:1 Redundancy for Traditional and HART I/O Cards: DeltaV redundant I/O uses the same Series 2 I/O cards as non-redundant I/O. This allows you to leverage your investment in installed I/O and in I/O spares. No additional configuration is needed when using a redundant channel. The redundant terminal blocks provide the same field wiring connections as simplex blocks, so there is no extra wiring needed.
Autosense of Redundancy: DeltaV autosenses redundant I/O, which greatly simplifies the task of adding redundancy to the system. The redundant pair of cards is treated as one card in the system tools.

Technical Specifications at a Glance

Model NumberKJ1501X1-BA2
Product TypeSystem Power Supply (AC/DC)
SeriesDeltaV M-series
Input Voltage120/230 VAC
Output Voltage12V DC / 24V DC (nominal)
MountingI/O interface carrier (DIN rail)
CompatibilityMQ, MX, PK controllers; M-series horizontal & VerticalPlus carriers
RedundancySupported (1:1 for I/O cards)
ProtectionIn-line fuses, bussed power
Operating Temperature-40 to 70°C (-40 to 158°F)
Storage Temperature-40 to 85°C (-40 to 185°F)
Relative Humidity5 to 95%, non-condensing
Airborne ContaminantsISA-S71.04-1985 Class G3 Conformal Coating
Protection RatingIP 20

M-Series System Power Supply Model Variants

The DeltaV M-series power supply family includes multiple model numbers to meet different system configurations and redundancy requirements. If you are sourcing a specific variant, the following related models may also be available:
KJ1501X1-BA1M-series System Power Supply (AC/DC)
KJ1501X1-BA2
M-series System Power Supply (AC/DC) – Current Model
KJ1501X1-BB1M-series System Power Supply (AC/DC)
KJ1501X1-BC2M-series System Power Supply (AC/DC)
KJ1501X1-BC3 / VE5009M-series System Power Supply (AC/DC)
KJ1501X1-BC4M-series System Power Supply (AC/DC)
KJ1501X1-BK1M-series System Power Supply (AC/DC)
Note: Model availability may vary. Please contact us for current stock status and lead times.

Compatible DeltaV M-Series Components

The KJ1501X1-BA2 is designed to work with the following DeltaV M-series components:
Controllers:
  • MQ Controller

  • MX Controller

  • PK Controller

Carriers:
  • M-series Horizontal Carriers

  • M-series VerticalPlus Carriers

I/O Cards (Partial List):
  • AI, 8-Channel, 4-20 mA, HART

  • AO, 8-Channel, 4-20 mA, HART

  • DI, 8-Channel, 24V DC, Dry Contact

  • DO, 8-Channel, 24V DC, High-Side

  • RTD, 8-Channel

  • Thermocouple/mV, 8-Channel

  • DI, 32-Channel, 24V DC, Dry Contact

  • DO Plus, 32-Channel, 24V DC, High-Side

  • AI Plus, 16-Channel, 4-20 mA, HART

  • AO Plus, 16-Channel, 4-20 mA, HART

Termination Blocks:
  • Standard I/O Termination Blocks

  • Fused I/O Termination Blocks

  • Mass Termination Blocks (10-pin, 16-pin, 24-pin, 40-pin, 48-pin)

  • Redundant Termination Blocks


Certifications and Approvals

The DeltaV M-series I/O subsystem, including the KJ1501X1-BA2 system power supply, carries the following certifications:
  • CE: EMC – EN 61326-1

  • FM: FM 3600, FM 3611

  • CSA: CSA C22.2 No. 213, CSA C22.2 No. 1010-1

  • ATEX: EN 60079-0, EN 60079-7, EN 60079-15

  • IEC Ex: IEC 60079-0, IEC 60079-7, IEC 60079-15

  • Marine: IACS E10, ABS Certificate of Design Assessment, DNV Marine Certificate

Hazardous Area Classifications:
  • FM (USA): Class I, Division 2, Groups A, B, C, D, T4

  • cFM (Canada): Class I, Division 2, Groups A, B, C, D, T4

  • ATEX: II 3G Ex ec IIC T4 Gc

  • IEC Ex: II 3G Ex ec IIC T4 Gc


System Compatibility Notes

The KJ1501X1-BA2 system power supply is compatible with:
  • DeltaV v11.3.1 and later (for S-series and M-series controllers on the same Area Control Network)

  • DeltaV v13.3.1 or higher (required for traditional I/O Plus cards)

  • M-series traditional I/O horizontal carriers (not physically compatible with S-series horizontal controller carriers)

Important: M-series I/O interfaces must be installed with M-series controllers, and S-series I/O interfaces with S-series controllers. Mixing carrier types is not supported.

Ordering Information

DeltaV M-series System Power Supply (AC/DC)KJ1501X1-BA2
Prerequisites:
  • Each controller requires a dedicated system power supply.

  • M-series I/O interface carrier required for mounting

  • DeltaV v11.3.1 or later software


Frequently Asked Questions

Q: Is the KJ1501X1-BA2 still available?
A: Availability may vary. Please contact us directly for current stock status, lead times, and pricing.
Q: What is the difference between KJ1501X1-BA2 and other M-series power supply models?
A: The KJ1501X1-BA2 is one of several M-series system power supply variants. Differences may include output configuration, compatibility with specific controller models, or certification ratings. Please refer to the specific model specifications or contact us for assistance.
Q: Can the KJ1501X1-BA2 be used in redundant configurations?
A: Yes. The M-series power architecture supports 1:1 redundancy for critical I/O cards. The KJ1501X1-BA2 provides the power foundation for redundant I/O configurations.
Q: What controllers are compatible with the KJ1501X1-BA2?
A: The KJ1501X1-BA2 is compatible with MQ, MX, and PK controllers, as well as M-series horizontal and VerticalPlus carriers.
Q: Does the KJ1501X1-BA2 support hot-swap replacement?
A: In safe areas, failed cards can be replaced under power. In hazardous areas, appropriate installation procedures must be followed. Always refer to the installation instructions for your specific application.

Why Choose Us for Your KJ1501X1-BA2 Power Supply

We specialize in sourcing hard-to-find and discontinued Emerson DeltaV components, including the KJ1501X1-BA2 system power supply and the complete M-series power supply family. Our team understands the urgency of process control maintenance — when a power supply fails, every minute of downtime matters.
What we offer:
  • In-Stock Availability: Ready-to-ship inventory for critical spares

  • Competitive Pricing: Cost-effective solutions for new and legacy DeltaV systems

  • Technical Expertise: Support from engineers who understand DeltaV architecture

  • Fast Quotes: Quick turnaround on pricing and availability requests

  • Global Shipping: Delivery to your site, wherever you are


Request a Quote Today

Ready to source your Emerson DeltaV KJ1501X1-BA2 System Power Supply?
Contact us now for:
  • Current stock availability

  • Pricing and lead times

  • Technical specifications and compatibility questions

  • Bulk or project-based quotations

Email: [your email]
Phone: [your phone number]
Website: [your website]
We respond to all inquiries within 24 hours.

Related Products You May Need

DeltaV M-series System Power SupplyKJ1501X1-BA1
DeltaV M-series System Power SupplyKJ1501X1-BB1
DeltaV M-series System Power SupplyKJ1501X1-BC2
DeltaV M-series System Power SupplyKJ1501X1-BC3 / VE5009
DeltaV M-series System Power SupplyKJ1501X1-BC4
DeltaV M-series System Power SupplyKJ1501X1-BK1
DeltaV SX ControllerSE3007
DeltaV SQ ControllerSE3008
DeltaV Bulk Power Supply (24V DC, 5A)VE5138
DeltaV Bulk Power Supply (24V DC, 10A)VE5123
DeltaV Bulk Power Supply (24V DC, 20A)VE5126
DeltaV Bulk Power Supply (24V DC, 40A)VE5128
DeltaV Bulk Power Supply Redundancy Module (20A)VE5134
DeltaV Bulk Power Supply Redundancy Module (40A)VE5135
DeltaV Bulk Power Supply Redundancy Module (80A)VE5136
All trademarks and brand names are the property of their respective owners. This article is for informational purposes and does not imply affiliation with or endorsement by Emerson Electric Co.