News
Get to know our latest news
RTU560 product line
Source: | Author:kongjiang | Published time: 2025-08-22 | 1 Views | 🔊 Click to read aloud ❚❚ | Share:
RTU560 product line

RTU560 product line

Communication module of the RTU560 with 32 bit CPU

• 6x serial communication interface (RS-232 or RS-485) for remote communication 

• 2x Ethernet interface (10/100BaseT) 

• 1x USB port 

• 1x serial peripheral bus 

• battery buffered real time clock

Application

The 560CMR02 communication unit is one of the CMU modules of the RTU560 product line.

The essential tasks are:

• Managing and controlling of the I/O modules via the interface to the serial I/O bus. 

• Reading Process events from the input modules.

• Send commands to the output modules. 

• Communicating with control systems and local HMI systems via the serial interface (RS232) and the Ethernet 10/100BaseT interfaces.

• Communication with Sub-RTU’s, IED’s or multimeter devices via the interfaces (RS485) and the Ethernet interfaces.

• Managing the time base for the RTU560 product line station and synchronizing the I/O modules. 

• Handling the dialog between RTU560 product line and Web-Browser via the LAN interfaces.

Within the RTU560 racks the board occupies two slots. The communication unit is able to handle Ethernet- and UART-character based communication protocols.

The unit has a battery buffered real time clock (RTC).

The unit is available in 2 versions: 

 • R0001: with standard cyber security functions 

 • R0002: with security chip for advanced cyber security functions

Characteristics

On the applied ARM cortex A8 controller AM3352 a real time operating system is implemented. The 560CMR02 is responsible for the interface management, the event handling, the time base and the internal data base. The controller acts as master for the SPB I/O bus (serial peripheral bus). RTU560 synchronizes itself to the time references supplied by 560RTC0x. The time information of the 560RTC0x is provided to the 560CMR02 on the backplane of the sub-rack.

System relevant configuration files are stored in the non volatile flash memory card (removable SD-card™) in order to guarantee a valid system configuration after Power on Reset (PoR).

A battery buffered RTC is used to keep an exact time during power off state.

The communication unit provides the following interfaces:

• Communication Port 1 ... 6 (CP1 ... CP6): serial interfaces according RS232C or RS485 with RJ45 connectors. CP1 and CP2 can be configured independant as SPB I/O bus interface to the front. 

• Ethernet interface 1 and 2 (E1 & E2): 10/100BaseT with RJ45 connector. 

• USB 2.0 device interface for diagnosis and maintenance purposes. 

• The SPB I/O bus is directly connected to the backplane connector.

Same series model

ABB Hitachi 560CVD03R0041
ABB Hitachi 560CVD03R0051 
ABB Hitachi SCADA   560CMU05 
ABB SCADA   560PSU01 
ABB 560PSR00 
ABB 560CMR02 R0001 
ABB 560BOR01 R0002 
ABB 560BIR01 R0002

ABB LDMUI-01  61320946C

ABB XVC724BE102 3BHE009017R0102

ABB UFC921A 3BHE024856P201

ABB UAC389 HIEE410506P104

ABB BN5930

ABB NTAC-02 58967441E

ABB CT-APS.22 1SVR630180R3300

ABB SZ4127.000

ABB GRBTU-01 3BSE013175R1

ABB RM302024

ABB RM602024

ABB LT2005-S/SP19

ABB B09261

ABB KTO 011  KTO011

ABB KTS 011  KTS011

ABB TNR 25590  TNR25590

ABB "3BHE006373R0101 XVC769 AE101

HIEE410506P104"

ABB SCYC51204 63912476

ABB SCYC51204 63912476C

ABB SCYC51213 63911607C

ABB FPX86-9364-A