  • TRICONEX 3504E 24 VDC /48 VDC High-Density Digital Input (TMR)
    TRICONEX 3504E 24 VDC /48 VDC High-Density Digital Input (TMR)
    TRICONEX 3504E 24 VDC /48 VDC High-Density Digital Input (TMR)
    TRICONEX 3504E 24 VDC /48 VDC High-Density Digital Input (TMR)
    ❤ Add to collection
  • TRICONEX 3504E 24 VDC /48 VDC High-Density Digital Input (TMR)

    TRICONEX 3504E 24 VDC /48 VDC High-Density Digital Input (TMR) I/O and Communication Module Slot Keys

    • U.S.$51006.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:1.390KG
    • Quantity:
    • (Inventory: 99999)
Description

TRICONEX 3504E 24 VDC /48 VDC High-Density Digital Input (TMR) I/O and Communication Module Slot Keys


Installing Modules
This procedure explains how to install a module.
WARNING: Do not install more than one module at the same time. You must push the WARNING first module in and wait until the Active indicator turns on, then install the next module.
Procedure
1 Ensure that the slots have been fitted for the appropriate module. For details, see Slot Keys for Modules on page 242.
2 Install the module and push the module in until it is firmly seated. Tighten the module's retractable fasteners to 10 inch-pounds.
3. If using a redundant module, install an identical type module in the empty slot and push the module in until it is firmly seated. Tighten the module's retractable fasteners to 10 inch-pounds.
Digital Output Field Wiring Precautions
When installing field wiring for Digital Output Modules, Invensys recommends that you do not make parallel connections or series connections to digital output points. These types of connections can cause the commanded state and the measured state of points to disagree, resulting in Load/Fuse alarms and limited effectiveness of Output Voter Diagnostics (OVD).
Pulse Input Module Installation and Operation
Pulse Input Module installation includes these requirements for proper operation.
Installation Requirements
• Wire each point with individually shielded, twisted-pair cable. Keep the wire as short as possible. Connect the shield to earth ground at the sensor or the controller. Where possible, route the cable away from all noise sources.
• To minimize signal reflections, put a termination resistor (1 to 10 kilohms) on each input signal. Mount the termination resistor at the termination panel across the positive (+) and negative (–) input terminals.
• Short together the positive (+) and negative (–) terminals of all unused inputs.
Using with Amplified Sensors or Laboratory Pulse Generators
• Where possible, use an amplifier or pulse generator with a fully balanced output (an isolated output stage). When using an amplified speed sensor, a lower-value termination resistor is acceptable (50 to 150 ohms).


Model

3501E/T

3502E

3503E

3504E

3505E

3510

3511

3515

3564

3601E/T

3603B

3603E/T

3604E

3607E

3611E

3613E

3614E

3615E


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
Product List