Introduction
This manual contains information on installation, operation, adjustment, and
troubleshooting for the 4–20 mA speed-setting system for UG-10 governors
(UG-10 MAS). The manual does not describe the operation of the UG-10D (dial)
governors. For complete operation of the UG dial governors, see manual 03040.
Description
The speed-setting system consists of an electronic control amplifier which
accepts the 4–20 mA signal and drives a stepper motor, which is mounted on the
cover of the UGD (UG Dial) governor. This unit in turn rotates the speeder rod
which sets the speed of the UGD governor. Chapter 4 contains a detailed
description of operation. The control amplifier is housed in a small cast aluminum
case (see Figure 1-2). The stepper motor and the feedback potentiometer are
mounted in the aluminum cover which is part of the UGD governor (see Figures
1-1 and 1-2).
Applications
The speed setting system is designed around a UGD type of governor to enable
its speed to be set from a remote location using a 4–20 mA current loop.
Its principal aim is to meet the need for remote control of engine speed in marine
applications using milliamp signals instead of the more traditional pneumatic
pressure signal. It can, however, be used in other situations where a UGD
governor is applicable.
Some of the UG auxiliary functions (such as solenoid shutdown) can be
incorporated. Please consult Woodward about new applications.