Describe
Central module microprocessor with two clock-synchronous microprocessors, Intel 386EX, 32-bit clock frequency 25 MHz, memory operating system Flash-EPROM 1 MB, user program Flash-EPROM 1 MB, data SRAM 1 MB utilization depends on operating system version interface two serial interfaces RS 485, four-bit matrix display with electrical isolation diagnosis display, optional information with fail-safe related monitor is turned off, with an output of 24 V, which can load up to 500 mA. There are two European standard PCBs with a short-circuit prevention structure, and one PCB is used for diagnosing display space requirements of 8 SU, operating at 5 V/2 A.

For the serial interface, only the bus station no. 1-31 can be set. Within an Ethernet network, the bus station no. can be set from 1 to 99. Therefore, the switches S1-6/7 must be set in addition to the switches S1-1/2/3/4/5. The number of communication partners within a network is still limited to 64. This enhanced setting of the bus station no. is only possible with the operating system BS41q/51q V7.0-8 (05.31) of the central module.
Applications with the communication module F 8627X: – connection of the central module to a PADT (ELOP II TCP) – connection to other communication partners within an Ethernet network (safeEthernet, Modbus TCP). The communication runs from the central module via the backplane bus to the communication module F 8627X and from the Ethernet ports of the F 8627X into the Ethernet network and vice versa.
Special features of the central module: – Self-education: from operating system BS41q/51q V7.0-8 (05.31) – ELOP II TCP: from operating system BS41q/51q V7.0-8 (05.31).

Further information about the bus station no., ELOP II TCP, loading of operating systems and application programs (self-education), et al., corresponding to the central module, you will find in the data sheet of the F8627X as well as the operating system manual of H41q/H51q and the safety manual of H41q/H51q. For a complete overview, consult these documents to support the central module’s full use.
Before removing a central module, its fixing screws must be completely loosened and freely movable. Remove the module from the bus board by pushing the ejection lever (front label) top down and quickly removing it in an upward motion to ensure that faulty signals are not triggered within the system!
To attach the module, place it on the terminal block and press it inwards as far as it will go. This action should be performed quickly to ensure that faulty signals are not triggered within the system!

Processor module X-CPU 01 is used for high performance requirements and large-scale security applications, 4 x RJ-45.
Processor module X-CPU 31 is used for small and medium-sized security applications, 4 x RJ-45.
System bus module X-SB 01
Communication modules X-COM 01 4 x RJ-45, 2 x 9-pole D-Sub, up to six different protocols.
Type description of input/output module
input module
Digital input module X-DI 64 01 64 channels, 24 VDC, SIL 3
Digital input module X-DI 64 51 64 channels, 24 VDC
Digital input module X-DI 32 01 32 channels, 24 VDC, SIL 3
Digital input module X-DI 32 02 32 channels, 8.2 VDC, proximity switch, line monitoring, SIL 3.
Digital input module X-DI 32 03 32 channels, 48 VDC, SIL 3
Digital input module X-DI 32 04 32 channels, 24 VDC, SOE, SIL 3
Digital input module X-DI 32 05 32 channels, 8,2 VDC, proximity switch, line monitoring, SOE, SIL 3.
Digital input module X-DI 32 51 32 channels, 24 VDC
Digital input module X-DI 32 52 32 channels, 8,2 VDC, proximity switch, line monitoring.
Digital input module X-DI 16 01 16 channels, 120 VAC, SIL 3
Analog input module X-AI 16 51 16 channels, 0/4 … 20 mA, ±280 mV, electrical isolation, thermocouple TC, Pt100.
Analog input module X-AI 32 01 32 channels, 4 ... 20 mA, line monitoring, SIL 3.
Analog input module X-AI 32 02 32 channels, 4 ... 20 mA, line monitoring, SOE, SIL 3.
Analog input module X-AI 32 51 32 channels, 0/4 ... 20 mA, line monitoring.
Counter module X-CI 24 01 24 channels, 0 ... 20 kHz, SIL 3
Counter module X-CI 24 51 24 channels, 0 ... 20 kHz
output module
Digital output module X-DO 32 01 32 channels, 24 VDC, 0.5 A, short circuit monitoring LS, single channel closed, SIL 3.
Digital output module X-DO 32 51 32 channels, 24 VDC, 0.5 A, protected output, group off.
Digital output module X-DO 24 01 24 channels, 24 VDC, 0.5 A, line monitoring LS/LB, individual channel closed, SIL 3.
Digital output module X-DO 24 02 24 channels, 48 VDC, 0.5 A, line monitoring LS/LB, individual channel closed, SIL 3.
Relay output module X-DO 12 01 12 channels, 230 VAC/DC, current measurement, cycle counting, SIL 3.
Digital output module X-DO 12 02 12 channels, 24 VDC, 2 A, short circuit monitoring LS, single channel off, SIL 3.
Relay output module X-DO 12 51 12 channels, 230 VAC/DC.
Analog output module X-AO 16 01 16 channels, 4 ... 20 mA, electrically isolated in pairs.
Analog output module X-AO 16 51 16 channels, 4 ... 20 mA
More modules
HART communication module X-HART 32 01 32 modem, SIL 3, X-AI 32 01, X-AI 32 02, X-AI 32 51, X-AO 16 01, X-AO 16 51.
Overspeed trip module X-MIO 7/6 01 3 counters, 4 digital inputs, 5 digital outputs, 1 relay channel, SIL 3.
Dimension type description
All module dimensions are 310 x 29 x 230 mm.