English
News
Get to know our latest news
GUTOR PDW Industrial Three-Phase Online Double Conversion UPS
Source: | Author:kongjiang | Published time: 2026-07-02 | 33 Views | 🔊 Click to read aloud ❚❚ ▶ | Share:
GUTOR PDW Industrial Three-Phase Online Double Conversion UPS

Safeguard Critical Power in the Harshest Industrial Environments

Introduction

From nuclear power plant instrumentation, oil & gas refineries, thermal power stations, chemical facilities, to rail transit systems, any grid fluctuation, power outage or electrical noise can trigger production shutdowns, safety hazards and massive financial losses.
The GUTOR PDW series is an industrial online double-conversion three-phase UPS built with thyristor-controlled rectifiers and IGBT-PWM inverters. Equipped with galvanic isolation transformers, seismic-resistant enclosures and IEC 60880 nuclear-grade compliance, it delivers uninterrupted, long-backup, ultra-reliable and fully customised power protection for mission-critical loads, operating steadily under extreme conditions including high temperature, dust, vibration and heavy electromagnetic interference.

1. Robust Industrial Build for Severe Operating Conditions

Designed to withstand the toughest industrial environments with comprehensive structural, coating and material upgrades:

Full Galvanic Isolation Protection

A transformer base delivers complete galvanic isolation to eliminate electric shock risks and suppress harmful electrical noise, isolating stray ground potential interference for impulse nonlinear loads such as motors and inverters. Tinned copper bars are available as an optional upgrade for corrosive, humid and chemical environments.

Wide Temperature & Humidity Tolerance

  • Operating temperature range: -10°C to +55°C; storage temperature: -20°C to +70°C

  • All printed circuit boards feature conformal coating to defend against moisture, dust, chemicals and extreme temperature swings.

  • Accepts up to 95% non-condensing relative humidity, ideal for coastal, chemical and underground facilities

Seismic Reinforced Enclosure

  • Certified for seismic resistance up to 1.0 g peak spectral acceleration; structural reinforcements available upon request for high-seismic zones.

  • Standard IP20 ingress protection, upgradable to IP42 / NEMA 2 for dust and splash resistance

  • Standard light grey RAL 7035 industrial paint; custom cabinet colours supported

Redundant Cooling for Low Maintenance

N+1 monitored two-speed fans eliminate single-point cooling failure. Noise output ranges from 60 to 75 dBA depending on the model, with system efficiency up to 91% to balance stable heat dissipation and energy consumption.

2. Nuclear-Grade Reliable Architecture Eliminating Single Points of Failure

PDW’s controller firmware and hardware fully comply with IEC 60880 for nuclear power plant safety applications, with a multi-redundant design to maximise system availability.

Mature Double-Conversion Power Topology

The 6-pulse thyristor rectifier can simultaneously deliver 100% rated load power and boost-charge batteries to support extended backup durations. It outputs pure sinusoidal power:
  • Static voltage regulation: ±1% across 0–100% load

  • Dynamic voltage deviation: ±4% under full-load surge

  • Regulation recovery time: <25 ms

  • THD ≤3% for linear loads; ≤5% for nonlinear loads per IEC 62040-3

Multi-Level Overload & Short-Circuit Protection

  • Continuous operation at 105% load; 125% overload for 10 minutes; 150% overload for 1 minute

  • Inverter limits short-circuit current to 200% of the rated value within 100 ms.

  • Static bypass withstands inrush current up to 10× nominal input current.

  • IEC 60269 standard gG fuses clear faults within 10 ms to prevent fault propagation

Parallel & Redundant Scalability

Supports standalone operation, N+1 redundant parallel systems and dual parallel load-sharing configurations for flexible capacity expansion.
Independent System Surveillance (ISS) continuously monitors all critical components (rectifier, inverter, bypass, battery) to avoid system lockup or unplanned shutdown.
Separate modular rectifier and inverter power blocks can be stocked as spare parts to minimise downtime, featuring industry-leading high MTBF, long service life and minimal routine maintenance.

Universal Battery Compatibility

Supports lead-acid, NiCd, lithium-ion and sodium nickel batteries with DC voltage options of 110 / 125 / 220 / 400 VDC. Fully programmable charging parameters:
  • Float voltage: 100–115% adjustable

  • Boost equalisation voltage: 100–125% adjustable.

  • Boost charge duration: 1–24 hours programmable.

  • Built-in functions include automatic battery capacity discharge test, battery temperature monitoring and DC ground fault alarm for full battery safety oversight.

3. Fully Customisable Design for Global Industrial Applications

Wide Voltage & Power Range

  • Rectifier / bypass three-phase input voltages: 380 / 400 / 415 / 480 / 600 / 690 V and custom options for global grids

  • Three-phase output voltages: 208 / 380 / 400 / 415 V

  • Power ratings: 20 kVA to 220 kVA; higher capacities and special voltages available on request

  • Intermediate DC bus voltages: 110 / 125 / 220 / 400 VDC to match all battery bank setups

Extensive Optional Add-Ons

  • Power quality optimisation: Input harmonic filter, bypass stabiliser transformer, voltage limiting unit for Forsmark event compliance

  • Power distribution: Built-in battery MCCB, downstream distribution panels, Independent Static Bypass Switch (ISBS), output EA static switch

  • Monitoring accessories: 72×72 / 96×96 analogue & digital meters, battery monitoring system, battery coupling device, space heaters, air filters

  • Safety upgrades: AC & DC ground fault alarms, custom cabinet footprint, cabinet panel lighting

Intuitive HMI & Full-Spectrum Industrial Communication

Multilingual Local Operator Interface

7 selectable display languages with dedicated LED alarm indicators for clear real-time status visibility. Supports automatic boost equalisation, battery capacity testing and time/date configuration, with a timestamped event log recording all mode changes and fault alarms.

Full Industrial Protocol Connectivity

  • 16 fail-safe NO/NC relay contacts for external alarm linkage

  • Native support for Modbus, TCP/IP, IEC 61850 and RS485

  • Embedded web server for remote monitoring; seamless integration with EcoStruxure platforms

  • Cybersecurity compliant with IEC 62443, meeting GDPR and California SB-327 data security requirements for nuclear and industrial control networks

Comprehensive Real-Time Measurement & Alarm System

Monitored parameters include load percentage, rectifier input V/I, bypass voltage, DC bus & battery V/I, inverter output electrical metrics and peak output current. An optional battery monitor calculates remaining backup runtime.
Full alarm coverage covers input power loss, inverter failure, fan fault, battery discharge, over-temperature, manual bypass activation, asynchronous out-of-sync and dozens more critical statuses with audible/visual alert linkage.

4. Global Standard Compliance & Target Applications

Certifications & Standards

  • Safety: IEC/EN 62040-1, UL1778, CSA 22.2-107.3

  • EMC: IEC/EN 62040-2, FCC Part 15 Subpart B Class A

  • Performance: IEC/EN 62040-3, NEMA PE-1

  • Environmental: REACH, RoHS 2011/65/EU, CE marking

  • Special industry: IEC 60880 nuclear compliance, 1.0 g seismic certification

Key Application Sectors

  1. Energy Industry: Nuclear plant safety I&C, thermal power DCS, wind & solar central control, offshore oil & gas platforms, refinery automation

  2. Heavy Industry: Chemical production lines, metallurgy precision control, rail transit signal systems

  3. Advanced Infrastructure: Industrial laboratories, precision manufacturing instruments, water treatment safety interlock systems

5. Why Choose GUTOR PDW Industrial UPS?

  1. Nuclear-Grade Safety Benchmark: One of the only three-phase UPS ranges certified to IEC 60880 for nuclear safety, with top-tier seismic and hardware security standards

  2. All-Environment Adaptability: Engineered for high temperature, high humidity, dust, seismic activity and heavy electromagnetic interference with no extra room modification required

  3. Fully Customised Delivery: Voltage, power rating, ingress protection, communication, battery and cabinet configurations tailored to non-standard industrial projects

  4. Low Total Cost of Ownership: High MTBF, modular spare parts and redundant cooling cut annual maintenance costs and eliminate costly unplanned downtime

  5. Digital-Ready Intelligent Monitoring: Multilingual local panel, web remote access and multi-bus industrial communication for factory centralised digital management

  6. Extended Backup Capacity: High-power charging circuits support large battery banks to realise multi-hour long-duration backup power

GUTOR OP2446