With 12 switchgear control elements, a fully configurable single-line diagram on a large color graphical display, a 36-alarm integrated annunciator panel, and up to 20 virtual pushbuttons, the 8 Series eliminates the need for external controls, switches, and annunciation on the panel, reducing equipment and engineering costs.
.jpg)
Same Look and Feel: Unified protection, control, and monitoring experience across feeders, motors, transformers, and generators
One Box Solution: Advanced logic and configuration flexibility for comprehensive primary or backup protection, control, and monitoring
Configurable SLD: User-configurable single-line diagram with color display for local control, system status, and metering
Advanced Diagnostics: High-end motor, transformer, and generator diagnostics with fault and disturbance recording
Integrated Arc Flash Protection: Light sensors supervised by overcurrent to reduce incident energy and equipment damage
High-End Cyber Security: AAA, RADIUS, RBAC, and Syslog enabling NERC CIP compliance
Draw-Out Design: Simplifies testing, commissioning, and maintenance, increasing uptime
Optional Wi-Fi Connectivity: Minimizes system configuration and provides safe relay programming and diagnostic retrieval
Environmental Diagnostics: Real-time visibility on changes in environmental parameters
.jpg)
Advanced Communications: IEC 61850 Ed2, IEC 62439/PRP, Modbus RTU & TCP/IP, DNP3.0, IEC 60870-5-104, IEC 60870-5-103
Single Setup & Configuration: Across the entire platform
Field Swappable Power Supply: Extends usable life and minimizes replacement costs
Enhanced Draw-Out Construction: Simplifies device fleet management
Elimination of Electrolytic Capacitors: Enhances long-term reliability.
Fast Protection Pass: Runs every 2 ms for faster response on current, voltage, power, and frequency elements
.jpg)
IPC A-610-E Class 3 Manufacturing: Drives to the highest level of reliability standards
100% Environmental Stress Screening: Full functional testing prior to shipping
IP54 Rated (Front): Suitable for harsh industrial environments
Harsh Environment Coating: Standard on all printed circuit boards
10-Year Worldwide Warranty: Designed, tested, and assembled by GE Vernova
EnerVista Software Suite: Complete setup, monitoring, and maintenance tools
| 850 | Feeder Protection System | Advanced protection, control & diagnostics for distribution feeders; 2 CB control and 4-shot auto reclose |
850P | Multi-feeder Protection | Advanced multi-feeder solution; draw-out construction with field swappable power supply |
| 845 | Transformer Protection System | Winding hot spots, internal short circuit, high oil temperature; fault analysis tools |
| 869 | Motor Management System | Stator winding overheating & turn-to-turn fault detection, broken rotor bar protection, bearing temperature monitoring; Motor Health Report |
| 889 | Generator Protection System | Advanced unit differential protection, generator monitoring & diagnostics, 100% stator ground protection |
| 12/14 | Over Speed / Under Speed Protection | — | — | — | — | — | ● |
| 21YN | Neutral Admittance | — | — | — | — | — | ● |
| 24 | Volts per Hertz | — | — | — | — | ● | ● |
| 25 | Synchrocheck | — | — | — | — | — | ● |
| 27P | Phase Undervoltage | ● | ● | ● | — | ● | ● |
| 27Q | UV Reactive Power | — | — | — | — | — | ● |
| 27TN | Third Harmonic Neutral Undervoltage | — | — | — | — | — | ● |
| 27TT | Timed Undervoltage Protection | — | — | — | — | ● | ● |
| 27X | Auxiliary Undervoltage | ● | ● | ● | — | ● | ● |
| 32 | Directional Power | ● | ● | ● | — | ● | ● |
| 32N | Wattmetric Ground Fault | ● | ● | ● | — | — | — |
| 37 | Undercurrent | ● | ● | ● | ● | — | — |
| 37P | Underpower | — | — | — | ● | — | — |
| 38 | Bearing RTD Temperature | — | — | — | ● | — | — |
| 39 | Bearing Vibration (dcmA) | — | — | — | ● | — | — |
| 40 | Loss of Excitation | — | — | — | — | — | ● |
| 40Q | Reactive Power | — | — | — | — | — | ● |
| 46 | Current Unbalance | ● | ● | ● | ● | — | ● |
| 47 | Phase Reversal | ● | ● | ● | ● | — | ● |
| 49 | Thermal Overload | ● | ● | ● | ● | ● | — |
| 49S | Stator RTD Temperature | — | — | — | ● | — | — |
| 49TOL | Thermal Overload | — | — | — | ● | — | — |
| 50/27 | Inadvertent Energization | — | — | — | — | — | ● |
| 50/87 | Instantaneous Differential Overcurrent | — | — | — | — | — | ● |
| 50BF | Breaker Failure | ● | ● | ● | — | — | ● |
| 50G | Ground Instantaneous Overcurrent | ● | ● | ● | ● | ● | ● |
| 50SG | Sensitive Ground Instantaneous Overcurrent | ● | ● | ● | ● | — | ● |
| 50LR | Mechanical Jam | — | — | — | ● | — | — |
| 50N | Neutral Instantaneous Overcurrent | ● | ● | ● | ● | ● | ● |
| 50P | Phase Instantaneous Overcurrent | ● | ● | ● | ● | ● | ● |
| 50_2 | Negative Sequence Instantaneous Overcurrent | — | — | — | — | — | ● |
| 51G | Ground Time Overcurrent | ● | ● | ● | ● | ● | ● |
| 51SG | Sensitive Ground Time Overcurrent | ● | ● | ● | — | — | — |
| 51N | Neutral Time Overcurrent | — | — | — | — | ● | ● |
| 51P | Phase Time Overcurrent | ● | ● | ● | ● | ● | ● |
| 51V | Voltage Restrained Time Overcurrent | — | — | — | — | — | ● |
| 51_2 | Negative Sequence Time Overcurrent | — | — | — | — | — | ● |
| 52 | AC Circuit Breaker | — | — | — | ● | — | — |
| 55 | Power Factor | — | — | — | ● | — | — |
| 59N | Neutral Overvoltage | — | — | — | — | ● | ● |
| 59P | Phase Overvoltage | ● | ● | ● | — | ● | ● |
| 59X | Auxiliary Overvoltage | — | — | — | — | ● | ● |
| 59_2 | Negative Sequence Overvoltage | — | — | — | — | — | ● |
| 64TN | 100% Stator Ground using 3rd Harmonic Voltage Differential | — | — | — | — | — | ● |
| 66 | Maximum Starting Rate | — | — | — | ● | — | — |
| 67G | Ground Directional Element | — | — | — | — | ● | ● |
| 67SG | Sensitive Ground Directional Element | — | — | — | — | — | ● |
| 67N | Neutral Directional Element | — | — | — | — | — | ● |
| 67P | Phase Directional Element | — | — | — | — | — | ● |
| 67_2 | Negative Sequence Directional Element | — | — | — | — | — | ● |
| 76 | Excitation Current Protection (dcmA) | — | — | — | — | — | ● |
| 78 | Out-of-Step Protection | — | — | — | — | — | ● |
| 79 | Automatic Recloser | ● | ● | ● | — | — | — |
| 81O | Overfrequency | — | — | — | — | — | ● |
| 81U | Underfrequency | — | — | — | — | — | ● |
| 81R | Frequency Rate of Change | — | — | — | — | — | ● |
| 86 | Start Inhibit | — | — | — | ● | — | — |
| 87G | Restricted Ground Fault (RGF) | — | — | — | — | ● | ● |
| 87GD | Restricted Ground Fault (RGF) | — | — | — | — | — | ● |
| 87O | Overall Unit (Gen-Xfrm) Protection | — | — | — | — | — | ● |
| 87S | Stator Differential | — | — | — | — | — | ● |
| 87T | Transformer Differential | — | — | — | — | ● | — |
| AFP | Arc Flash Protection | ● | ● | ● | — | — | — |
| CLP | Cold Load Pickup | — | — | — | — | — | ● |
| 11/12 | Broken Conductor | — | — | — | — | — | ● |
| MTM | Automatic Bus Transfer Scheme | — | — | — | — | — | ● |
| MCB | Manual Close Blocking | — | — | — | — | — | ● |
| SOTF | Switch on to Fault | ● | ● | ● | — | ● | ● |
| TGFD | Transient Ground Fault Detection | — | — | — | — | — | ● |
| VTFF | Voltage Transformer Fuse Failure | ● | ● | ● | — | ● | ● |