3500/95 monitorBently Nevada 3500/95 integrated PC monitor is a panel-mounted industrial computer running 3500 operator display software. It can visualize the data of single or multiple 3500 racks locally or remotely, and support RS-232, RS-422, and Ethernet communication for mechanical protection systems.
Overview
Bently Nevada 3500/95 system integrated PC monitor is a panel-mounted industrial computer specially designed for the 3500 mechanical protection platform. The device is pre-installed with 3500 data acquisition and operator display software, which can visualize all key information generated by the 3500 mechanical protection system locally and remotely.
A single 3500/95 monitor can retrieve and display monitoring data from multiple 3500 racks. Other software tools, including 3500 configuration software and other Bently Nevada condition monitoring applications, can also be installed on this integrated industrial PC.
The device can be installed in the same cabinet through the panel cut, or at a distance of 4000 feet from the 3500 rack with appropriate cables and RS-422 communication protocol.
Core function
-Panel-mounted industrial integrated computer with touch screen and color TFT display.
-2.0 GHz Celeron processor, equipped with 40GB hard disk, CD, serial, parallel, USB, and Ethernet interfaces.
-Runs Windows operating system and local 3500 operator display software.
-Supports monitoring one or more 3500 racks.
-Visualizes system event log, alarm event list, channel status, and rack configuration data.
-Communication options: RS-232, RS-422, and 10/100 Base-T Ethernet for LAN connection.
-RS-422 communication requires an adapter, Bently Nevada part number 02230411.
-Supports remote access to rack configuration and status viewing.
-Needs an external power supply
Field operation
3500/95 operator software provides real-time operation data for maintenance and operation teams;
-System event list
-Alarm event list
-Channel measurement status
-3500 rack configuration for local or remote access
Communication and installation
3500/95 integrated PC monitor is directly connected to the frame interface module through an RS-232 or RS-422 serial port.
Users can connect devices to the LAN through their 10/100 Base-T Ethernet ports.
For long-distance deployment: using RS-422 and a matching cable, the monitor can be installed at a distance of up to 4000 feet from the 3500 system rack. It is designed for installation through the panel opening in the control cabinet.
Spare part
3500/95-01
3500/95-02
3500/95-04
3500/95-01-00
3500/95-02-00
3500/95-04-00
3500/95-01-01
3500/95-03-01
3500/95-04-01
3500/95-01-02
3500/95-02-02
3500/95-03-02
3500/95-04-02
3500/95-02-03
3500/95-03-03
3500/95-04-03
145168-01
128158-01
3500/01-01